{"product_id":"eaton-fdm30-medium-voltage-fire-pump-controller","title":"Eaton FDM30 Medium Voltage Fire Pump Controller (EPCT Fire)","description":"\u003cp\u003eThe \u003cstrong\u003eEaton FDM30\u003c\/strong\u003e is the medium voltage model in Eaton's EPCT Fire line of electric fire pump controllers, for across-the-line starting of fire pump motors from 2,200V up to 6,900V. It pairs the EPCT Fire 7\" touchscreen with Eaton's AMPGARD medium voltage motor control design. Every FDM30 is built to order, so we quote each one to your motor, voltage, enclosure and options. Call \u003ca href=\"tel:+17863365783\"\u003e(786) 336-5783\u003c\/a\u003e or send us your catalog number or spec section.\u003c\/p\u003e\n\n\u003ch2\u003eMedium voltage construction\u003c\/h2\u003e\n\u003cp\u003eThe FDM30 is based on Eaton's AMPGARD controller design and uses the TRITON SL Series medium voltage vacuum contactor. Its vacuum interrupters offer long electrical life and high interruption capacity. Integral current-limiting fuses provide interrupting ratings of 200 MVA at 2,400V, 400 MVA at 3,000–4,160V and 570 MVA at 4,800–6,900V.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDraw-out isolating switch:\u003c\/strong\u003e externally operated, three-pole, grounds and isolates the starter when open, with provisions for three padlocks in the off position\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical interlocks\u003c\/strong\u003e that prevent entry into the high-voltage area while the starter is energized\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolated low-voltage control compartment\u003c\/strong\u003e with its own access door, and all components accessible from the front\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpare fuse storage\u003c\/strong\u003e inside the enclosure, per NFPA 20, plus a built-in test circuit for checking the control circuit with high voltage isolated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEmergency start handle\u003c\/strong\u003e that mechanically closes the motor contactor independently of the control circuits\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eEPCT Fire touchscreen features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e7\" color touchscreen:\u003c\/strong\u003e 800x480 high-resolution display, a fast processor that reduces input lag, and a simplified tab system to program site-specific setpoints, view critical system information and troubleshoot with on-screen diagnostics\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUSB port:\u003c\/strong\u003e download history, statistics, configuration, diagnostics and start-up files; upload a configuration to reduce programming time; update firmware\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvent history:\u003c\/strong\u003e logs up to 65,000 time-stamped events, with on-screen filtering for troubleshooting\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional boards:\u003c\/strong\u003e\n  \u003cul\u003e\n  \u003cli\u003eRelay board: four (4) one form-C programmable output relays\u003c\/li\u003e\n  \u003cli\u003eMODBUS board: output communication via RS422 or RS485\u003c\/li\u003e\n  \u003cli\u003eSecondary 4-20mA device board: additional connections for external pressure transducers, temperature sensors and similar devices\u003c\/li\u003e\n  \u003cli\u003eAlarm board: a supervisory powered alarm output\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosures:\u003c\/strong\u003e UL Type 2 (drip-proof) freestanding standard; Type 3, 3R, 4, 4X and 12 available\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e built to NFPA 20 and listed to UL 218. See the bid submittal for the full list of approvals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFDM30 ratings\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eLine voltage\u003c\/th\u003e\n\u003cth\u003eMotor horsepower\u003c\/th\u003e\n\u003cth\u003eInterrupting rating\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e2,200 – 2,400V\u003c\/td\u003e\n\u003ctd\u003e100 – 1,000 HP\u003c\/td\u003e\n\u003ctd\u003e200 MVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3,000V\u003c\/td\u003e\n\u003ctd\u003e100 – 1,250 HP\u003c\/td\u003e\n\u003ctd\u003e400 MVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3,300 – 3,600V\u003c\/td\u003e\n\u003ctd\u003e100 – 1,500 HP\u003c\/td\u003e\n\u003ctd\u003e400 MVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4,160V\u003c\/td\u003e\n\u003ctd\u003e100 – 2,000 HP\u003c\/td\u003e\n\u003ctd\u003e400 MVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4,800V\u003c\/td\u003e\n\u003ctd\u003e100 – 2,250 HP\u003c\/td\u003e\n\u003ctd\u003e570 MVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5,500V\u003c\/td\u003e\n\u003ctd\u003e100 – 2,750 HP\u003c\/td\u003e\n\u003ctd\u003e570 MVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6,000 – 6,300V\u003c\/td\u003e\n\u003ctd\u003e100 – 3,000 HP\u003c\/td\u003e\n\u003ctd\u003e570 MVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6,600 – 6,900V\u003c\/td\u003e\n\u003ctd\u003e100 – 3,250 HP\u003c\/td\u003e\n\u003ctd\u003e570 MVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eFDM30 catalog numbers explained\u003c\/h2\u003e\n\u003cp\u003eFDM catalog numbers follow their own pattern, with medium voltage codes. For example, \u003cstrong\u003eFDM30-1000-E-L1\u003c\/strong\u003e is a 1,000 HP, 4,160V\/60Hz medium voltage controller with English labels in the standard enclosure.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSegment\u003c\/th\u003e\n\u003cth\u003eExample\u003c\/th\u003e\n\u003cth\u003eMeaning\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel and starting type\u003c\/td\u003e\n\u003ctd\u003eFDM30\u003c\/td\u003e\n\u003ctd\u003eFDM = medium voltage fire pump controller · 30 = across-the-line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHorsepower\u003c\/td\u003e\n\u003ctd\u003e1000\u003c\/td\u003e\n\u003ctd\u003eMotor HP, from 100 to 3,250 HP depending on voltage (see ratings above)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage (60Hz)\u003c\/td\u003e\n\u003ctd\u003eE\u003c\/td\u003e\n\u003ctd\u003eA = 2,200–2,400V · B = 3,000V · C = 3,300V · D = 3,600V · E = 4,160V · F = 4,800V · G = 5,500V · H = 6,000V · J = 6,300V · K = 6,600V · L = 6,900V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage (50Hz)\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eM = 2,200–2,400V · N = 3,000V · P = 3,300V · Q = 3,600V · R = 4,160V · S = 4,800V · T = 5,500V · U = 6,000V · V = 6,300V · W = 6,600V · X = 6,900V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLanguage\u003c\/td\u003e\n\u003ctd\u003eL1\u003c\/td\u003e\n\u003ctd\u003eL1 English · L2 French · L4 Italian · L5 Spanish · L6 Portuguese · L7 Chinese · L8 Polish · L9 Dutch · L11 Turkish\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptions\u003c\/td\u003e\n\u003ctd\u003e(none)\u003c\/td\u003e\n\u003ctd\u003eAdded codes for enclosures and accessories (see below)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eFDM options\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eA \/ B\u003c\/td\u003e\n\u003ctd\u003eBuilt-in alarm system \/ alarm bell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC1 – C5\u003c\/td\u003e\n\u003ctd\u003eExtra contacts, two form-C (pump run, AC power failure, phase reversal, low and high reservoir)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOM\u003c\/td\u003e\n\u003ctd\u003eCommunications option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE2 \/ E5 \/ E9 \/ E10\u003c\/td\u003e\n\u003ctd\u003eNEMA 4 \/ NEMA 4X 304 stainless \/ NEMA 4X painted steel \/ NEMA 4X 316 stainless\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE8 \/ EX\u003c\/td\u003e\n\u003ctd\u003eTropicalization \/ export crating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eF2\u003c\/td\u003e\n\u003ctd\u003eFloor stand, 2 inch height (not available with NEMA 4 or 4X)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eP7 \/ P8 \/ P10\u003c\/td\u003e\n\u003ctd\u003eLow suction pressure switch with pilot light \/ low suction shutdown \/ sea water rated pressure transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eR1 – R7\u003c\/td\u003e\n\u003ctd\u003eSpace heaters, with thermostat or humidistat options; R4 low pump room temperature switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTBE \/ USB\u003c\/td\u003e\n\u003ctd\u003eTerminal block enclosure \/ externally mounted USB port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eLow voltage or medium voltage?\u003c\/h2\u003e\n\u003cp\u003eThe FDM30 is for fire pump motors fed at 2,200V and above. For services up to 600V, see the low voltage EPCT Fire controllers, starting with the \u003ca href=\"\/products\/eaton-fd30-across-the-line-fire-pump-controller\"\u003eFD30 across-the-line\u003c\/a\u003e and the reduced-voltage \u003ca href=\"\/products\/eaton-fd60-autotransformer-fire-pump-controller\"\u003eFD60\u003c\/a\u003e, \u003ca href=\"\/products\/eaton-fd70-wye-delta-open-fire-pump-controller\"\u003eFD70\u003c\/a\u003e, \u003ca href=\"\/products\/eaton-fd80-wye-delta-closed-fire-pump-controller\"\u003eFD80\u003c\/a\u003e and \u003ca href=\"\/products\/eaton-fd90-soft-start-fire-pump-controller\"\u003eFD90\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch2\u003eWhat we need for a quote\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMotor horsepower\u003c\/li\u003e\n\u003cli\u003eLine voltage and frequency (50 or 60Hz)\u003c\/li\u003e\n\u003cli\u003eEnclosure type\u003c\/li\u003e\n\u003cli\u003eOptions and label language\u003c\/li\u003e\n\u003cli\u003eSite altitude, if outside the standard -1,000 to +2,000 meter range\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eHave a full catalog number, a spec section or a photo of an existing nameplate? Send that instead and we'll match it. Call \u003ca href=\"tel:+17863365783\"\u003e(786) 336-5783\u003c\/a\u003e or \u003ca href=\"\/pages\/contact\"\u003erequest a quote\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch2\u003eBid submittal and documents\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.eaton.com\/content\/dam\/eaton\/products\/safety-security-emergency-communications\/fire-pump-controllers\/documents\/br124073en-epct-fire-bid-submittal-fdm30-medium-voltage.pdf\" target=\"_blank\" rel=\"noopener\"\u003eEPCT Fire – FDM30 – Medium Voltage Bid Submittal (PDF, eaton.com)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eReplacement parts\u003c\/h2\u003e\n\u003cp\u003eNeed parts for an existing Eaton fire pump controller? Browse all \u003ca href=\"\/collections\/spare-parts\"\u003eEaton fire pump controller replacement parts\u003c\/a\u003e or call us with your part number.\u003c\/p\u003e\n\n\u003cp\u003e\u003cem\u003eInstallation, wiring and commissioning should follow Eaton's instruction manual and NFPA 20 and be performed by qualified personnel.\u003c\/em\u003e\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":52185085640950,"sku":null,"price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/6907\/8774\/files\/FDM30.webp?v=1793828823","url":"https:\/\/thefirepump.com\/products\/eaton-fdm30-medium-voltage-fire-pump-controller","provider":"TheFirePump.com","version":"1.0","type":"link"}