{"product_id":"eaton-ft30-across-the-line-fire-pump-controller-with-ats","title":"Eaton FT30 Across-the-Line Fire Pump Controller with Automatic Transfer Switch","description":"\u003cp\u003eThe \u003cstrong\u003eEaton FT30\u003c\/strong\u003e is the across-the-line model with automatic transfer switch in Eaton's EPCT Fire line of electric fire pump controllers. It combines a full-service, full-voltage controller and a fire-pump-rated automatic transfer switch in one assembly. Every FT30 is built to order, so we quote each one to your motor, voltage, enclosure and options. Call \u003ca href=\"tel:+17863365783\"\u003e(786) 336-5783\u003c\/a\u003e or send us your catalog number or spec section.\u003c\/p\u003e\n\n\u003ch2\u003eHow the FT30 works\u003c\/h2\u003e\n\u003cp\u003eThe FT30 applies full line voltage to the motor at start through a single motor contactor. Starting inrush current is approximately 600% of the motor's rated full load amperes. The integrated automatic transfer switch moves the fire pump to an alternate power source, such as a generator or second utility feed, when the normal source fails, and the EPCT Fire touchscreen manages both the controller and the transfer switch from one display. The FT30 can be programmed for fully automatic or semi-automatic operation.\u003c\/p\u003e\n\u003cp\u003eFT30 controllers are supplied as dual utility controllers and meet FM 1321\/1323 approvals. Where the utility or site limits inrush, reduced-voltage models with transfer switch are available: \u003ca href=\"\/products\/eaton-ft40-part-winding-fire-pump-controller-with-ats\"\u003eFT40 part winding\u003c\/a\u003e, \u003ca href=\"\/products\/eaton-ft60-autotransformer-fire-pump-controller-with-ats\"\u003eFT60 autotransformer\u003c\/a\u003e, \u003ca href=\"\/products\/eaton-ft70-wye-delta-open-fire-pump-controller-with-ats\"\u003eFT70\u003c\/a\u003e and \u003ca href=\"\/products\/eaton-ft80-wye-delta-closed-fire-pump-controller-with-ats\"\u003eFT80 wye-delta\u003c\/a\u003e, and \u003ca href=\"\/products\/eaton-ft90-soft-start-fire-pump-controller-with-ats\"\u003eFT90 soft start\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch2\u003eEPCT Fire features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e7\" color touchscreen:\u003c\/strong\u003e 800x480 high-resolution display, a fast processor that reduces input lag, and a simplified tab system for navigation and programming\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUSB port:\u003c\/strong\u003e download history, statistics, configuration, diagnostics and start-up files; upload a configuration to reduce programming time; update firmware\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvent history:\u003c\/strong\u003e logs up to 65,000 time-stamped events, with on-screen filtering for troubleshooting\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgrammable output relays\u003c\/strong\u003e for common alarm, power\/phase failure, phase reversal and pump run\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional boards:\u003c\/strong\u003e\n  \u003cul\u003e\n  \u003cli\u003eRelay board: four (4) one form-C programmable output relays\u003c\/li\u003e\n  \u003cli\u003eMODBUS board: output communication via RS422 or RS485\u003c\/li\u003e\n  \u003cli\u003eSecondary 4-20mA device board: additional connections for external pressure transducers, temperature sensors and similar devices\u003c\/li\u003e\n  \u003cli\u003eAlarm board: a supervisory powered alarm output\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosures:\u003c\/strong\u003e UL Type 2 (drip-proof) standard; Type 3, 3R, 4, 4X and 12 available\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e built to NFPA 20, listed to UL 218, and FM 1321\/1323 approved. See the bid submittal for the full list of approvals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFT30 catalog numbers explained\u003c\/h2\u003e\n\u003cp\u003eEvery EPCT Fire catalog number follows the same pattern. For example, \u003cstrong\u003eFT30-100-D-L1\u003c\/strong\u003e is a 100 HP, 480V\/60Hz across-the-line controller with transfer switch and English labels in the standard enclosure.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSegment\u003c\/th\u003e\n\u003cth\u003eExample\u003c\/th\u003e\n\u003cth\u003eMeaning\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel and starting type\u003c\/td\u003e\n\u003ctd\u003eFT30\u003c\/td\u003e\n\u003ctd\u003eFT = controller with transfer switch · 30 = across-the-line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHorsepower\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003ctd\u003eMotor HP, from 5 to 700 HP. Not every HP is available at every voltage.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003ctd\u003eA = 208V\/60Hz · B = 240V\/60Hz · C = 380V\/50Hz · D = 480V\/60Hz · E = 600V\/60Hz · F = 415V\/50Hz · H = 380V\/60Hz · J = 400V\/50Hz · K = 400V\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLanguage\u003c\/td\u003e\n\u003ctd\u003eL1\u003c\/td\u003e\n\u003ctd\u003eL1 English · L2 French · L4 Italian · L5 Spanish · L6 Portuguese · L7 Chinese · L8 Polish · L9 Dutch · L11 Turkish\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptions\u003c\/td\u003e\n\u003ctd\u003e(none)\u003c\/td\u003e\n\u003ctd\u003eAdded codes for enclosures and accessories (see below)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCommon options\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eE1 \/ E2 \/ E3 \/ E4\u003c\/td\u003e\n\u003ctd\u003eNEMA 3R \/ NEMA 4 \/ NEMA 12 \/ NEMA 3 enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE5 \/ E9 \/ E10\u003c\/td\u003e\n\u003ctd\u003eNEMA 4X: 304 stainless \/ painted steel \/ 316 stainless\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eF2\u003c\/td\u003e\n\u003ctd\u003eFloor stand, 2 inch height (not available with NEMA 3, 4 or 4X)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eH \/ I\u003c\/td\u003e\n\u003ctd\u003eHigh or intermediate withstand rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOP1 – OP4\u003c\/td\u003e\n\u003ctd\u003eRelay board, MODBUS board, secondary 4-20mA device card, alarm board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC1 – C5, CX\u003c\/td\u003e\n\u003ctd\u003eExtra contacts (pump run, AC power failure, phase reversal, reservoir levels, custom)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eP7 \/ P8\u003c\/td\u003e\n\u003ctd\u003eLow suction pressure switch \/ low suction shutdown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eR1 – R7\u003c\/td\u003e\n\u003ctd\u003eSpace heaters, with thermostat or humidistat options\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003ctd\u003eAlarm bell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eSee the full \u003ca href=\"\/pages\/eaton-epct-fire-option-selection-matrix\"\u003eEPCT Fire option selection matrix\u003c\/a\u003e for every code.\u003c\/p\u003e\n\n\u003ch2\u003eFT30, FD30 or FD30 with FPATS?\u003c\/h2\u003e\n\u003cp\u003eIf the fire pump doesn't need automatic transfer, the stand-alone \u003ca href=\"\/products\/eaton-fd30-across-the-line-fire-pump-controller\"\u003eFD30 across-the-line controller\u003c\/a\u003e is the simpler option. Where the controller and transfer switch need to be separate, an FD30 can be paired with an \u003ca href=\"\/products\/eaton-fpats-fire-pump-automatic-transfer-switch\"\u003eFPATS stand-alone transfer switch\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch2\u003eWhat we need for a quote\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMotor horsepower\u003c\/li\u003e\n\u003cli\u003eLine voltage, phase and frequency\u003c\/li\u003e\n\u003cli\u003eAlternate power source (generator or second utility feed)\u003c\/li\u003e\n\u003cli\u003eEnclosure type\u003c\/li\u003e\n\u003cli\u003eOptions and label language\u003c\/li\u003e\n\u003cli\u003eWithstand rating, if your project requires high or intermediate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eHave a full catalog number, a spec section or a photo of an existing nameplate? Send that instead and we'll match it. Call \u003ca href=\"tel:+17863365783\"\u003e(786) 336-5783\u003c\/a\u003e or \u003ca href=\"\/pages\/contact\"\u003erequest a quote\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch2\u003eBid submittal and documents\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.eaton.com\/content\/dam\/eaton\/products\/safety-security-emergency-communications\/fire-pump-controllers\/documents\/bn124034en-epct-fire-ft30-bid-submittal.pdf\" target=\"_blank\" rel=\"noopener\"\u003eEPCT Fire – FT30 – Bid Submittal (PDF, eaton.com)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/eaton-epct-fire-option-selection-matrix\"\u003eEPCT Fire option selection matrix\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eReplacement parts\u003c\/h2\u003e\n\u003cp\u003eKeeping an existing EPCT Fire controller in service? Shop \u003ca href=\"\/collections\/electric-epct-fire-components\"\u003eEPCT Fire replacement components\u003c\/a\u003e, \u003ca href=\"\/collections\/electric-transfer-switch-components\"\u003etransfer switch components\u003c\/a\u003e, or browse all \u003ca href=\"\/collections\/spare-parts\"\u003eEaton fire pump controller replacement parts\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003cp\u003e\u003cem\u003eInstallation, wiring and commissioning should follow Eaton's instruction manual and NFPA 20 and be performed by qualified personnel.\u003c\/em\u003e\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":52185087049974,"sku":null,"price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/6907\/8774\/files\/FT30.webp?v=1793829155","url":"https:\/\/thefirepump.com\/products\/eaton-ft30-across-the-line-fire-pump-controller-with-ats","provider":"TheFirePump.com","version":"1.0","type":"link"}