{"product_id":"eaton-xtjp-jockey-pump-controller","title":"Eaton XTJP Jockey Pump Controller (JOCKEY Touch)","description":"\u003cp\u003eThe \u003cstrong\u003eEaton XTJP\u003c\/strong\u003e is Eaton's JOCKEY Touch across-the-line jockey pump controller. It keeps fire protection system pressure up by running the jockey pump, and it uses a microprocessor-based color touchscreen to monitor and program every function and value. Standard configurations are available to order online below; other configurations are built to order and quoted to your motor, voltage, enclosure and options. Call \u003ca href=\"tel:+17863365783\"\u003e(786) 336-5783\u003c\/a\u003e or send us your part number.\u003c\/p\u003e\n\n\u003ch2\u003eHow the XTJP works\u003c\/h2\u003e\n\u003cp\u003eThe XTJP operates across-the-line: full voltage is applied to the motor for starting through a single motor starter, with starting inrush current of approximately 600% of the motor's rated full load amperes. Pressure input comes from a 4-20mA pressure sensor, and start and stop points are adjustable in 1 PSI (or 0.1 BAR) increments. For jockey pump motors that need reduced-voltage starting, see the \u003ca href=\"\/products\/eaton-xtjy-wye-delta-jockey-pump-controller\"\u003eXTJY wye-delta jockey pump controller\u003c\/a\u003e. For a simpler pressure-switch-based controller, see the \u003ca href=\"\/products\/eaton-xtjl-jockey-lite-pump-controller\"\u003eXTJL Jockey Lite\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch2\u003eJOCKEY Touch features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor touchscreen:\u003c\/strong\u003e door-mounted, type 4\/4X rated display showing supply voltage on all phases, current pressure, start pressure and stop pressure, with programming possible with the door closed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCombination motor controllers:\u003c\/strong\u003e Eaton combination motor controllers combine the circuit breaker and overload in one device\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSealed rotary handle:\u003c\/strong\u003e can be padlocked in the OFF position, and is interlocked so the door can't be opened with the handle ON except by a tool-operated defeater\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUniversal supply voltage:\u003c\/strong\u003e auto-detects three phase supply from 200–600VAC 50\/60Hz and single phase from 110–240VAC 50\/60Hz, with no control transformer needed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eXT power controls:\u003c\/strong\u003e Eaton XT components with global ratings, compact size and a modular, plug-in design\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFour starting methods:\u003c\/strong\u003e auto, hand, remote start and pump start\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgrammable functions:\u003c\/strong\u003e two inputs, two output relays, five timers (minimum run, sequential start, pump run restart, acceleration and fail to start) and two virtual LEDs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlarm setpoints\u003c\/strong\u003e for phase reversal, phase failure, overvoltage and undervoltage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHistory and diagnostics:\u003c\/strong\u003e 10,000 time-stamped messages, eight diagnostics and seven statistics; USB port to download message history and upload firmware\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosures:\u003c\/strong\u003e NEMA 2 standard; NEMA 3R, 4, 4X and 12 available\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e meets NFPA 20 and CE mark requirements, meets or exceeds UL 508, and is CSA approved\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eRatings\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eLine voltage\u003c\/th\u003e\n\u003cth\u003eMotor horsepower\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e200–208V, three phase\u003c\/td\u003e\n\u003ctd\u003e1\/3 – 20 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e220–240V, three phase\u003c\/td\u003e\n\u003ctd\u003e1\/3 – 20 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e380–415V, three phase\u003c\/td\u003e\n\u003ctd\u003e1\/3 – 40 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e440–480V, three phase\u003c\/td\u003e\n\u003ctd\u003e1\/3 – 50 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e550–600V, three phase\u003c\/td\u003e\n\u003ctd\u003e1\/3 – 50 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e120V, single phase\u003c\/td\u003e\n\u003ctd\u003e1\/3 – 2 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e240V, single phase\u003c\/td\u003e\n\u003ctd\u003e1\/3 – 5 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eXTJP part numbers explained\u003c\/h2\u003e\n\u003cp\u003eXTJP part numbers are built around the motor's full load amperage. For example, \u003cstrong\u003eXTJP-G05-L1\u003c\/strong\u003e is a three phase controller for motors drawing 4.1–6.3 A, with English labels in the standard NEMA 2 enclosure.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSegment\u003c\/th\u003e\n\u003cth\u003eExample\u003c\/th\u003e\n\u003cth\u003eMeaning\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eXTJP\u003c\/td\u003e\n\u003ctd\u003eJOCKEY Touch across-the-line jockey pump controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage range\u003c\/td\u003e\n\u003ctd\u003eG05\u003c\/td\u003e\n\u003ctd\u003eThree phase: G01 0.6–1.0 A · G02 1.1–1.6 · G03 1.7–2.5 · G04 2.6–4.0 · G05 4.1–6.3 · G06 6.4–10.0 · G07 10.1–16.0 · G08 16.1–20.0 · G09 20.1–25.0 · G10 25.1–32.0 · G11 32.1–40.0 · G12 40.1–50.0 · G13 50.1–65.0\u003cbr\u003eSingle phase: G14 2.6–4.0 A · G15 4.1–6.3 · G16 6.4–10.0 · G17 10.1–16.0 · G18 16.1–20.0 · G19 20.1–25.0 · G20 25.1–32.0 · G21 32.1–40.0 · G22 40.1–50.0 · G23 50.1–65.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHorsepower and voltage (larger motors)\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eLarger units are specified by horsepower (15, 20, 25, 30, 40 or 50 HP) plus a voltage letter: A 208V\/60Hz · B 240V\/60Hz · C 380V\/50Hz · D 480V\/60Hz · E 600V\/60Hz · F 415V\/50Hz · H 380V\/60Hz · J 400V\/50Hz · K 400V\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLanguage\u003c\/td\u003e\n\u003ctd\u003eL1\u003c\/td\u003e\n\u003ctd\u003eL1 English · L2 French · L5 Spanish · L6 Portuguese · L11 Turkish\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptions\u003c\/td\u003e\n\u003ctd\u003e(none)\u003c\/td\u003e\n\u003ctd\u003eAdded codes for enclosures and accessories (see below)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eXTJP options\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eC1 \/ C2 \/ CX \/ FTS\u003c\/td\u003e\n\u003ctd\u003eExtra contacts: pump run \/ AC power failure \/ one form-C, specify function \/ fail to start\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE1 \/ E2 \/ E3\u003c\/td\u003e\n\u003ctd\u003eNEMA 3R \/ NEMA 4 \/ NEMA 12 enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE5 \/ E9 \/ E10\u003c\/td\u003e\n\u003ctd\u003eNEMA 4X: 304 stainless \/ painted steel \/ 316 stainless\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE8 \/ EX\u003c\/td\u003e\n\u003ctd\u003eTropicalization \/ export crating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePOL \/ PRL \/ LX\u003c\/td\u003e\n\u003ctd\u003e\"Power On\" virtual LED \/ \"Pump Run\" virtual LED \/ custom virtual LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eP7 \/ P8 \/ P10\u003c\/td\u003e\n\u003ctd\u003eLow suction pressure switch and alarm virtual LED \/ low suction shutdown (requires P7) \/ sea water rated pressure transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eR1 \/ R2 \/ R3\u003c\/td\u003e\n\u003ctd\u003eSpace heater \/ with thermostat \/ with humidistat (externally powered)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB\u003c\/td\u003e\n\u003ctd\u003eExternally mounted USB port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eXTJP controllers available to order online\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003cth\u003eSupply\u003c\/th\u003e\n\u003cth\u003eMotor full load amps\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/xtjp-g02-l1\"\u003eXTJP-G02-L1\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eThree phase\u003c\/td\u003e\n\u003ctd\u003e1.1–1.6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/xtjp-g03-l1\"\u003eXTJP-G03-L1\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eThree phase\u003c\/td\u003e\n\u003ctd\u003e1.7–2.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/xtjp-g04-l1\"\u003eXTJP-G04-L1\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eThree phase\u003c\/td\u003e\n\u003ctd\u003e2.6–4.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/xtjp-g05-l1\"\u003eXTJP-G05-L1\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eThree phase\u003c\/td\u003e\n\u003ctd\u003e4.1–6.3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/xtjp-g06-l1\"\u003eXTJP-G06-L1\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eThree phase\u003c\/td\u003e\n\u003ctd\u003e6.4–10.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/xtjp-g10-l1\"\u003eXTJP-G10-L1\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eThree phase\u003c\/td\u003e\n\u003ctd\u003e25.1–32.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/xtjp-g17-l1\"\u003eXTJP-G17-L1\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle phase\u003c\/td\u003e\n\u003ctd\u003e10.1–16.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/xtjp-g19-l1\"\u003eXTJP-G19-L1\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle phase\u003c\/td\u003e\n\u003ctd\u003e20.1–25.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eNot sure which size you need? Send us the motor nameplate full load amps, voltage and phase and we'll match it.\u003c\/p\u003e\n\n\u003ch2\u003eWhat we need for a quote\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eJockey pump motor full load amps (from the motor nameplate) and horsepower\u003c\/li\u003e\n\u003cli\u003eSupply voltage and phase\u003c\/li\u003e\n\u003cli\u003eEnclosure type\u003c\/li\u003e\n\u003cli\u003eOptions and label language\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eHave a full part number, a spec section or a photo of an existing nameplate? Send that instead and we'll match it. Call \u003ca href=\"tel:+17863365783\"\u003e(786) 336-5783\u003c\/a\u003e or \u003ca href=\"\/pages\/contact\"\u003erequest a quote\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch2\u003eBid submittals and documents\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eThree phase\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.eaton.com\/content\/dam\/eaton\/products\/safety-security-emergency-communications\/fire-pump-controllers\/documents\/br05805977k-c-xtjp-jy.pdf\" target=\"_blank\" rel=\"noopener\"\u003eBR05805977K – 3 Phase, standard NEMA 2, options (PDF, eaton.com)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.eaton.com\/content\/dam\/eaton\/products\/safety-security-emergency-communications\/fire-pump-controllers\/documents\/br05805877k-c-xtjp-jy.pdf\" target=\"_blank\" rel=\"noopener\"\u003eBR05805877K – 3 Phase, Large HP, standard NEMA 2, options (PDF, eaton.com)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.eaton.com\/content\/dam\/eaton\/products\/safety-security-emergency-communications\/fire-pump-controllers\/documents\/br05805777k-c-xtjp-jy.pdf\" target=\"_blank\" rel=\"noopener\"\u003eBR05805777K – 3 Phase, NEMA 12, 3R, 4, 4X, options (PDF, eaton.com)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSingle phase 120\/240V\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.eaton.com\/content\/dam\/eaton\/products\/safety-security-emergency-communications\/fire-pump-controllers\/documents\/br05805677k-c-xtjp-jy.pdf\" target=\"_blank\" rel=\"noopener\"\u003eBR05805677K – 1 Phase, standard NEMA 2, options (PDF, eaton.com)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.eaton.com\/content\/dam\/eaton\/products\/safety-security-emergency-communications\/fire-pump-controllers\/documents\/br05805577k-c-xtjp-jy.pdf\" target=\"_blank\" rel=\"noopener\"\u003eBR05805577K – 1 Phase, Large HP, standard NEMA 2, options (PDF, eaton.com)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.eaton.com\/content\/dam\/eaton\/products\/safety-security-emergency-communications\/fire-pump-controllers\/documents\/br05805477k-c-xtjp-jy.pdf\" target=\"_blank\" rel=\"noopener\"\u003eBR05805477K – 1 Phase, NEMA 12, 3R, 4, 4X, options (PDF, eaton.com)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eReplacement parts\u003c\/h2\u003e\n\u003cp\u003eKeeping an existing jockey pump controller in service? Shop \u003ca href=\"\/collections\/jockey-xtjp-xtjy-components\"\u003eXTJP\/XTJY components\u003c\/a\u003e, \u003ca href=\"\/collections\/jockey-touch-xtjp-xtjy-components\"\u003eJOCKEY Touch components\u003c\/a\u003e, or browse all \u003ca href=\"\/collections\/spare-parts\"\u003eEaton fire pump controller replacement parts\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003cp\u003e\u003cem\u003eInstallation, wiring and commissioning should follow Eaton's instruction manual and NFPA 20 and be performed by qualified personnel.\u003c\/em\u003e\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":52185091113206,"sku":null,"price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/6907\/8774\/files\/jockey-pump-controller.webp?v=1793830129","url":"https:\/\/thefirepump.com\/products\/eaton-xtjp-jockey-pump-controller","provider":"TheFirePump.com","version":"1.0","type":"link"}