{"product_id":"eaton-xtjy-wye-delta-jockey-pump-controller","title":"Eaton XTJY Wye-Delta Jockey Pump Controller (JOCKEY Touch)","description":"\u003cp\u003eThe \u003cstrong\u003eEaton XTJY\u003c\/strong\u003e is Eaton's JOCKEY Touch wye-delta (star-delta) jockey pump controller. It's used where a six or twelve-lead delta connected jockey pump motor needs reduced-voltage starting, and it uses the same microprocessor-based color touchscreen as the XTJP to monitor and program every function and value. Every XTJY is built to order, so we quote each one to your motor, voltage, enclosure and options. Call \u003ca href=\"tel:+17863365783\"\u003e(786) 336-5783\u003c\/a\u003e or send us your part number.\u003c\/p\u003e\n\n\u003ch2\u003eHow wye-delta jockey pump starting works\u003c\/h2\u003e\n\u003cp\u003eThe XTJY starts a six or twelve-lead delta connected motor in a wye (star) connection. Approximately 58% of line voltage is applied to each winding, so the motor develops 33% of full-voltage starting torque and draws 33% of normal locked-rotor current from the line. After an adjustable time delay, while the motor accelerates, the controller reconnects the motor in delta for normal operation. Wye-delta starting is for three phase motors only. For across-the-line starting, see the \u003ca href=\"\/products\/eaton-xtjp-jockey-pump-controller\"\u003eXTJP jockey pump controller\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch2\u003eJOCKEY Touch features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor touchscreen:\u003c\/strong\u003e door-mounted, type 4\/4X rated display showing supply voltage on all phases, current pressure, start pressure and stop pressure, with a 4-20mA pressure sensor adjustable in 1 PSI (or 0.1 BAR) increments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCombination motor controllers:\u003c\/strong\u003e Eaton combination motor controllers combine the circuit breaker and overload in one device\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSealed rotary handle:\u003c\/strong\u003e can be padlocked in the OFF position, and is interlocked so the door can't be opened with the handle ON except by a tool-operated defeater\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUniversal three phase supply:\u003c\/strong\u003e auto-detects three phase supply from 200–600VAC 50\/60Hz, with no control transformer needed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFour starting methods:\u003c\/strong\u003e auto, hand, remote start and pump start\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgrammable functions:\u003c\/strong\u003e two inputs, two output relays, five timers (including an acceleration timer for the wye-to-delta changeover) and two virtual LEDs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlarm setpoints\u003c\/strong\u003e for phase reversal, phase failure, overvoltage and undervoltage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHistory and diagnostics:\u003c\/strong\u003e 10,000 time-stamped messages, eight diagnostics and seven statistics; USB port to download message history and upload firmware\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosures:\u003c\/strong\u003e NEMA 2 standard; NEMA 3R, 4, 4X and 12 available\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e meets NFPA 20 and CE mark requirements, meets or exceeds UL 508, and is CSA approved\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eRatings\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eLine voltage (three phase)\u003c\/th\u003e\n\u003cth\u003eMotor horsepower\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e200–208V\u003c\/td\u003e\n\u003ctd\u003e1\/3 – 40 HP (0.74 – 29.42 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e220–240V\u003c\/td\u003e\n\u003ctd\u003e1\/3 – 40 HP (0.74 – 29.42 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e380–415V\u003c\/td\u003e\n\u003ctd\u003e1\/3 – 50 HP (0.74 – 36.78 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e440–480V\u003c\/td\u003e\n\u003ctd\u003e1\/3 – 50 HP (0.74 – 36.78 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e550–600V\u003c\/td\u003e\n\u003ctd\u003e1\/3 – 50 HP (0.74 – 36.78 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eXTJY part numbers explained\u003c\/h2\u003e\n\u003cp\u003eXTJY part numbers are built around the motor's full load amperage. For example, \u003cstrong\u003eXTJY-G10-L1\u003c\/strong\u003e is a wye-delta controller for three phase motors drawing 25.1–32.0 A, with English labels in the standard NEMA 2 enclosure.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSegment\u003c\/th\u003e\n\u003cth\u003eExample\u003c\/th\u003e\n\u003cth\u003eMeaning\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eXTJY\u003c\/td\u003e\n\u003ctd\u003eJOCKEY Touch wye-delta (star-delta) jockey pump controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage range\u003c\/td\u003e\n\u003ctd\u003eG10\u003c\/td\u003e\n\u003ctd\u003eG01 0.6–1.0 A · G02 1.1–1.6 · G03 1.7–2.5 · G04 2.6–4.0 · G05 4.1–6.3 · G06 6.4–10.0 · G07 10.1–16.0 · G08 16.1–20.0 · G09 20.1–25.0 · G10 25.1–32.0 · G11 32.1–40.0 · G12 40.1–50.0 · G13 50.1–65.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHorsepower and voltage (larger motors)\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eLarger units are specified by horsepower (15, 20, 25, 30, 40 or 50 HP) plus a voltage letter: A 208V\/60Hz · B 240V\/60Hz · C 380V\/50Hz · D 480V\/60Hz · E 600V\/60Hz · F 415V\/50Hz · H 380V\/60Hz · J 400V\/50Hz · K 400V\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLanguage\u003c\/td\u003e\n\u003ctd\u003eL1\u003c\/td\u003e\n\u003ctd\u003eL1 English · L2 French · L5 Spanish · L6 Portuguese · L11 Turkish\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptions\u003c\/td\u003e\n\u003ctd\u003e(none)\u003c\/td\u003e\n\u003ctd\u003eAdded codes for enclosures and accessories (see below)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eXTJY options\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eC1 \/ C2 \/ CX \/ FTS\u003c\/td\u003e\n\u003ctd\u003eExtra contacts: pump run \/ AC power failure \/ one form-C, specify function \/ fail to start\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE1 \/ E2 \/ E3\u003c\/td\u003e\n\u003ctd\u003eNEMA 3R \/ NEMA 4 \/ NEMA 12 enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE5 \/ E9 \/ E10\u003c\/td\u003e\n\u003ctd\u003eNEMA 4X: 304 stainless \/ painted steel \/ 316 stainless\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE8 \/ EX\u003c\/td\u003e\n\u003ctd\u003eTropicalization \/ export crating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePOL \/ PRL \/ LX\u003c\/td\u003e\n\u003ctd\u003e\"Power On\" virtual LED \/ \"Pump Run\" virtual LED \/ custom virtual LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eP7 \/ P8 \/ P10\u003c\/td\u003e\n\u003ctd\u003eLow suction pressure switch and alarm virtual LED \/ low suction shutdown (requires P7) \/ sea water rated pressure transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eR1 \/ R2 \/ R3\u003c\/td\u003e\n\u003ctd\u003eSpace heater \/ with thermostat \/ with humidistat (externally powered)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB\u003c\/td\u003e\n\u003ctd\u003eExternally mounted USB port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eWhat we need for a quote\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eJockey pump motor full load amps and horsepower, and confirmation it's a six or twelve-lead delta connected motor\u003c\/li\u003e\n\u003cli\u003eSupply voltage (three phase) and frequency\u003c\/li\u003e\n\u003cli\u003eEnclosure type\u003c\/li\u003e\n\u003cli\u003eOptions and label language\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eHave a full part number, a spec section or a photo of an existing nameplate? Send that instead and we'll match it. Call \u003ca href=\"tel:+17863365783\"\u003e(786) 336-5783\u003c\/a\u003e or \u003ca href=\"\/pages\/contact\"\u003erequest a quote\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch2\u003eBid submittals and documents\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.eaton.com\/content\/dam\/eaton\/products\/safety-security-emergency-communications\/fire-pump-controllers\/documents\/br05805377k-c-xtjy.pdf\" target=\"_blank\" rel=\"noopener\"\u003eBR05805377K – Wye-Delta, standard NEMA 2, options (PDF, eaton.com)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.eaton.com\/content\/dam\/eaton\/products\/safety-security-emergency-communications\/fire-pump-controllers\/documents\/br05805277k-d-xtjy.pdf\" target=\"_blank\" rel=\"noopener\"\u003eBR05805277K – Wye-Delta, Large HP, standard NEMA 2, options (PDF, eaton.com)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.eaton.com\/content\/dam\/eaton\/products\/safety-security-emergency-communications\/fire-pump-controllers\/documents\/br05805177k-d-xtjy.pdf\" target=\"_blank\" rel=\"noopener\"\u003eBR05805177K – Wye-Delta, standard and Large HP, NEMA 12, 3R, 4, 4X (PDF, eaton.com)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eReplacement parts\u003c\/h2\u003e\n\u003cp\u003eKeeping an existing jockey pump controller in service? Shop \u003ca href=\"\/collections\/jockey-xtjp-xtjy-components\"\u003eXTJP\/XTJY components\u003c\/a\u003e, \u003ca href=\"\/collections\/jockey-touch-xtjp-xtjy-components\"\u003eJOCKEY Touch components\u003c\/a\u003e, or browse all \u003ca href=\"\/collections\/spare-parts\"\u003eEaton fire pump controller replacement parts\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003cp\u003e\u003cem\u003eInstallation, wiring and commissioning should follow Eaton's instruction manual and NFPA 20 and be performed by qualified personnel.\u003c\/em\u003e\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":52185092030710,"sku":null,"price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/6907\/8774\/files\/XTJY.webp?v=1793830209","url":"https:\/\/thefirepump.com\/products\/eaton-xtjy-wye-delta-jockey-pump-controller","provider":"TheFirePump.com","version":"1.0","type":"link"}